SGL series water – cooled roller slag cooler

Short Description:

SGL series water-cooled roller slag cooler is a kind of general industrial water as the heat exchange medium.Special equipment for dry cooling and conveying high temperature slag of circulating fluidized bed boiler and boiling bed boiler.The equipment absorbs the advantages of various slag cooler on the market at the same time,Targeted to solve similar products in the use of the process of high failure rate,
A series of problems, such as large maintenance volume, short life cycle and high slag temperature,Greatly reduce the number of downtime and shorten the maintenance time, effectively ensure the continuous and stable operation of equipment.
SGL series water – cooled roller slag cooler mainly consists of spiral blades、Inner and outer sleeve,Feed and exhaust device,Water inlet and outlet device,Transmission device and base composition.When the drum is driven and rotated by the transmission device,The high-temperature slag discharged from the boiler is guided forward by spiral blades in the sleeve.Cooling water is continuously and uniformly passed through the sleeve sandwich and hollow blade,The cooling air is also constantly passing backwards through the sleeve,Cool the slag gradually.


Product Detail

Product Tags

Description

The outstanding features of SGL series water-cooled drum slag cooler are:
(1) Maintain slag activity: dry cooling is adopted to completely avoid contact with water slag. Maintain slag activity, so that the troublesome waste slag produced by the boiler into a good activity of cement and building materials additives.
(2) High thermal efficiency, large adaptability range of slag discharge temperature (40℃ ~ 220℃);
(3) The sleeve is used to rotate and push the material. There is no relative movement between the spiral blade and the cylinder. The structure is simple, the whole machine has high life, low power consumption and low noise.
(4) Excellent environmental protection and economic performance: no special requirements for cooling water, cooling water can use power plant circulating cooling water or general industrial water, no need to desalting and softening, can reduce capital investment and operation costs.
(5) Continuous slag discharge, the speed can be adjusted continuously in a large range according to the amount of slag. It is beneficial to stabilize the boiler bed pressure, maintain the thickness of the boiler combustion layer, and reduce the carbon content of slag.
(6) the cooling water discharge pipe is outside the cylinder, so the roller is safe, reliable and easy to maintain;
(7)Can be equipped with cooling water overtemperature alarm,Cut off the water and stop (and alarm)、Overpressure relief and other safety protection.

SGL series Water-cooled drum slag cooler

details

SGL series water-cooled drum slag cooler technical parameters

project parameter project project
The material temperature ≤1000℃ Cylinder speed 0.9~9.0 r/min
The grain-size ≤20mm Speed range 1.0~10.0 r/min
Outlet temperature ≤200℃ Equipment noise Meter away from the equipment :≤80 dB(A)
Inlet temperature of cooling water ≤25℃ The transmission way The gear drive
Cooling water outlet temperature ≤65℃ The water quality requirements General industrial water or softened water or desalinated water
Inlet pressure of cooling water ≤0.5Mpa Reducer type No. XWD4
Cooling water resistance ≤0.2MPa Speed way Frequency control of motor speed
Inlet and outlet diameter of cooling water Dg80 Cooling air Natural wind
Distance between import and export centers 4000~12000mm
model Processing power Cooling water consumption The motor power
SGL-6 0~6.0t/h  ≤20t/h 2.2Kw
SGL -8 0~8.0t/h ≤25t/h 2.2Kw
SGL-10 0~10.0t/h ≤30t/h 3.0Kw
SGL-12 0~12.0t/h ≤35t/h 4.0Kw